ICS Trusted Triple Modular Redundant (TMR) Systems
Description
Trusted System:
The Trusted® solution features a Triple Modular Redundant (TMR) controller. It is designed to provide maximum safety and system availability. Trusted uses control to minimize system trips and provides high availability, fault tolerance and fail-safe features as part of its intrinsic, safety-related functionality. The architecture features:
Trusted controller is a highly compact solution. It can hold up to 240 TMR I/O channels in a single Trusted controller chassis, including a spare processor, dual ethernet and multiple serial communications capability.
Trusted expander can connect up to 28 I/O expander chassis, totalling up to 128 I/O modules per system. The expander chassis may be located up to 5km away and are connected to the controller processor chassis by triplicated fiber optic links.
Trusted I/O modules are designed to meet the SIL 3 requirement, for both analog and digital signals. All models have full “stuck on / stuck off” signal testing and configurable line monitoring. Trusted offers a wide range of standard I/O module types including 120V AC and 125V DC inputs and outputs.
Modular power system can be powered directly from a single or dual conditioned 24V DC supply, or from AC power sources and redundant power feeds.
Benefits
Maximum Safety and Availability:
• A Safety Integrity Level of 3 (SIL3) and fault tolerant
• Stable, predictable operation
• High capacity and high speed
• Easy to use and maintain
• High density I/O (up to 60 channels/module)
Hardware Voting Technology:
• High test coverage of potential faults
• Tolerance to multiple failures
• No restrictions on time-to-repair
• Accurate fault identification
• Reduced operating system size and complexity
Comprehensive Programming Environment:
• IEC 61131 programming environments in five languages
• Define up to 250 programs per project
• Offline simulation, Online debug
Communications Options:
• Modbus TCP/IP, Modbus RTU and EtherNet/IP communications to Programmable Automation Controllers
• OPC DA (Data Access) & A&E (Alarm & Event) communications
Trusted supports a number of I/O modules that meet special process control requirements
The Valve Test module:
Partial stroke testing of critical valves is a crucial feature that meets the latest process safety standards. The Trusted system integrates automatic valve testing inside a TMR, TÜV approved SIL3 architecture, providing maximum safety and availability. With this package, you are able to periodically test the valve and actuator subsystem without shutting down your process.
The Zone Interface module:
The Trusted Zone Interface helps reduce the complexity of a Fire & Gas system by integrating all functions into a single module. It can be used in combination with any other Trusted hardware. The 40-channel Zone Interface module provides:
• Fault tolerant monitoring of any 4-20mA gas detector, in addition to any low-voltage digital signal, with line monitoring. These include flame, smoke or heat detectors and manual alarm call points.
• Outputs for the control and alarm of hazards as well as the calibration of detectors.
The Speed Monitor module:
Trusted offers a high integrity solution for the protection of gas/steam turbine acceleration and over-speed prevention. The module provides:
• Autonomous over-speed protection for up to three rotating machines. Each over-speed trip has three independent, fault tolerant speed inputs and a fault tolerant digital output.
• Speed inputs have a wide, dynamic range of 0.1 Hz to 30 kHz.
• Sequence-of-events reporting with a 1 ms resolution.
Stock part list:
T8100
T8110B
T8123
T8151B
T8153
T8191
T8193
T8292
T8293
T8300
T8310
T8311
T8312
T8403
T8431
T8431C
T8442
T8442C
T8461
T8480
T8480C
T8800
T8830
T8846
T8850
T8891
T9100
T9110
T9300(T9801)
T9300(T9851)
T9402
T9432
T9451
TC-201-02-4M5
T8231
T9310-02
T9482
T8831
T8801
T8314
T8231C
Post time: May-15-2026