page_banner

news

Description 

Advant Controller 450 is a high-end process controller. Its high processing capacity and wide-ranging process and system communication capabilities make it the ideal choice for demanding applications, either standing alone or as part of a ABB Ability™ System 800xA with Advant® Master.

Does everything in process control:

Advant Controller 450 can do “everything” in process control, not only perform logic, sequence, positioning and regulatory control but also manage data and text generally and produce reports. It can even perform selftuning adaptive, PID control and fuzzy logic control.

The station is programmed graphically in AMPL, as are all other controllers in Advant OCS with Master software. The already rich library of program elements/ function blocks can be augmented with user-developed blocks created in AMPL.

A full complement of I/O:

The range of process I/O modules is complete, covering general-purpose analog an digital inputs and outputs at different ratings as well as Pt100, thermocouple and pulse inputs. Specialized interfaces are provided for accurate digital positioning, switchgear integration, variable-speed motor control, telecontrol and communication with other makes of programmable controllers. The overall I/O capacity is as high as 5,700 I/O points.

Both central and distributed I/O are available:

Central I/O (S100 I/O) modules are plugged into I/O racks installed in close proximity to the CPU rack/ cabinet. Distributed I/O (S800 I/O) stations can be installed up to 13,3 km (8,2 miles) away, communicating over Advant Fieldbus 100, a high-speed serial communication bus.

The controller that stays in touch :

Advant Controller 450 supports a wide range ofcommunication protocols, making it easy to designthe optimal control system architecture for everyapplication. These protocols include:

MasterBus 300/300E for communication with othermember stations of Advant OCS at the ControlNetwork level.

GCOM for communication with AdvaSoft for Windowsand external computers. The easy, powerful, forexternal computers to access process data in AdvantOCS. Both ways.

Advant Fieldbus 100 for communication with distrib-uted l/O stations, programmable controllers andmotor drives.

RCOM/RCOM+ for long-distance communicationwith remote terminals, using dedicated or dial-uptelecommunication lines.

Redundancy at all levels:

To achieve the highest possible availability, Advant Controller 450 can be equipped with backup redundancy for MasterBus 300/300E, Advant Fieldbus 100, power supplies, voltage regulators, backup batteries, battery chargers, central units (CPUs and memories) and I/O boards for regulatory control.

The central unit redundancy is of a patented hot standby type, offering bumpless changeover in less than 25 ms.

Enclosures:

Advant Controller 450, equipped with local S100 I/O, consists of one CPU rack and up to five I/O racks. Optical bus extension makes it possible to distribute the S100 I/O up to 500 m (1,640 ft.) away, thus reducing the amount of field cabling required.

The I/O racks are designed for installation in cabinets with a swing-out frames, permitting access to both the front and the rear of racks for ease of installation and maintenance. The external connections are routed through connection units normally fitted inside, at the back of the cabinets for marshalling and noisesuppression purposes. Cabinets with various degrees of protection are available, e.g. ventilated, tropical and sealed, with or without heat exchangers.

Features

• Logic and sequence control.
• Data and text handling.
• Arithmetic, reporting and positioning.
• Regulatory control including Fuzzy control, advanced PID and self-tuning adaptive control.
• Highly extended flexibility and scalability – hardware as well as software.
• Fully modular with a controller subrack based on FB+ (IEEE 896) as the system bus.
• Self-configuration capabilities which make it possible to add units while the controller is in full operation
• Support of a wide range of central and distributed I/O modules for maximum configuration possibilities, with a maximum I/O capacity of 5700 I/O points.
• Support of local and central HMI for manual control operations, event and alarm handling, trend curve presentation etc.
• Interoperability concerning all communication levels from plant floor fieldbuses to high-speed plant network.
• Support of redundant Fieldbus Communication with Advant Fieldbus 100.
• Support of Advant Fieldbus 100 with cable length up to 13300 m (43300 feet).

Advant Controller 450 datasheet

Stock part list:

ABB DSDP 150 57160001-GF
ABB DSDP 170 57160001-ADF
ABB PM511V08 3BSE011180R1
ABB SC510 3BSE003832R1
ABB SR511 3BSE000863R1
ABB CI546 3BSE012545R1
ABB TC512V1 3BSE018059R1
ABB TC520 3BSE001449R1
ABB DSPC 172 57310001-ML
ABB CI522A 3BSE018283R1
PM510V16
PM511V16 3BSE011181R1
PU515A 3BSE032401R1
PU516
PM511V08
PM510V16 3BSE008358R1
PM511V16
SB510 3BSE000860R1
CS513 3BSE000435R1
RB520 3BSE003528R1
CI532V09 3BUP001190R1
CI534V02 3BSE010700R1
CI540 3BSE001077R1
CI520V1 3BSE012869R1
RF533 3BSE014227R1(BB510 3BSE001693R2)
SX554 3BSE004946R1
CI541V1 3BSE014666R1
CI570 3BSE001440R1
CI535V30 3BSE022162R1
CI535V26 3BSE022161R1
CI532V02 3BSE003827R1
CI545V01 3BUP001191R1
CI532V03 3BSE003828R1
PU514A 3BSE032400R1
MPP SC300E
MDI32BIS
SC520 3BSE003816R1
SC520M 3BSE016237R1
CI543 3BSE010699R1
BB510 3BSE001693R2
PU516A 3BSE032402R1
TC570 3BSE001458R1
RF520机架+底板BB510 3BSE000741R1
SB511 3BSE002348R1
AC450
3BSX755270R4
3BSX755125R4
3BSX489710R19 内存卡
3BSX703071R4 内存卡
CI535V23 3BSE022160R1
PU515 3BSE013063R1
RC527 3BSE008154R1
CI531 3BSE003825R1
RF522 3BSE000743R1(BB512 3BUR980001R0001)


Post time: Dec-29-2025