Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for Abb Cp800 , Abb 07di92 Gjr5252400r0101 , Main Chassis , Safety as a result of innovation is our promise to each other.
EA403 913-403-000-012 extension cable Supplier – Meggitt Vibro Meter IOC4T 200-560-000-016 input/output card – RuiMingSheng Detail:

Description

Manufacture Meggitt Vibro Meter
Model IOC4T
Ordering information 200-560-000-016
Catalog VM600
Description Meggitt Vibro Meter IOC4T 200-560-000-016 input/output card
Origin Switzerland
HS Code 85389091
Dimension 16cm*16cm*12cm
Weight 0.8kg

Details

IOC4T card
The IOC4T input /output card acts as a signal interface for the VM600 series MPC4 machinery protection card, from Meggitt’s Vibro-Meter® product line. It is installed in the rear of a VM600
rack and connects directly to the rack backplane via two connectors.

Each IOC4T card is associated with a corresponding MPC4 card and is mounted directly behind it in the VM600 rack (ABE04x or ABE056). The IOC4T operates in slave mode and communicates with the MPC4, through connector P2, using an Industry Pack (IP) interface.

The front panel of the IOC4T (rear of the VM600 rack) contains terminal strip connectors for wiring
to the transmission cables coming from measurement chains (sensors and /or signal conditioners). The screw-terminal connectors are also used to input all signals from and output all signals to any external control system.

The IOC4T card protects all inputs and outputs against electromagnetic interference (EMI) and signal surges and also meets electromagnetic compatibility (EMC) standards.

The IOC4T connects the raw dynamic (vibration) and speed signals from the sensors to the MPC4. These signals, once processed, are passed back to the IOC4T and made available on the terminal strip on its front panel (rear of VM600). For the dynamic signals, four on-board digital-to-analog converters (DACs) provide calibrated signal outputs in the range 0 to 10 V. In addition, four onboard onboard voltage-to-current converters allow the signals to be provided as current outputs in the range 4 to 20 mA (jumper selectable).

The IOC4T contains four local relays that can be attributed to any specific alarm signals under software control. For example, these may be used to signal an MPC4 fault or a problem detected by a common alarm (Sensor OK, Alarm and Danger)in a typical application.

In addition, 32 digital signals representing alarms are passed to the rack backplane and may be used by optional RLC16 relay cards and / or IRC4 intelligent relay cards mounted in the rack (jumper selectable).


Datasheet link


Product detail pictures:

EA403 913-403-000-012 extension cable Supplier –  Meggitt Vibro Meter IOC4T 200-560-000-016 input/output card – RuiMingSheng detail pictures


Related Product Guide:

As a result of ours specialty and service consciousness, our company has won a good reputation among customers all over the world for EA403 913-403-000-012 extension cable Supplier – Meggitt Vibro Meter IOC4T 200-560-000-016 input/output card – RuiMingSheng , The product will supply to all over the world, such as: Monaco, French, Mali, Regarding quality as survival, prestige as guarantee, innovation as motive force, development along with advanced technology, our group hopes to make progress together with you and make untiring efforts for the bright future of this industry.
  • The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Karl from Croatia - 2018.05.13 17:00
    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Chloe from Moldova - 2018.06.28 19:27

    Send your message to us: